+61412988527
7 Days a week from 9:00 am to 5:00 pm
UV Air Recirculator Defender 2-15C closed type is designed to clean and disinfect air in the presence of people. It can work continuously throughout the day, preventing an increase in the level of microbial contamination of indoor air, regardless of the number of people in it and its category. Defender 2-15C is used for air purification both in hospitals and educational institutions, kindergartens, beauty parlors, and cultural institutions. Also, can be used at home.
Volume of premises, m3
Recommended processing time (not less), min.
Residential apartments, smoking rooms, public toilets and staircases of hospitals Children's playrooms, school classes, orphanages, homes for the disabled, household premises of industrial and public buildings with a large crowd of people during a long stay Chambers, offices and other premises of health care facilities (premises of the III category)
up to 60 60 90 120
from 60 to 120 120 180 240
Number of germicidal lamps 2
Nominal lamp power, W 15
The performance of the irradiator with a bactericidal efficiency of % (for Staphylococcus aureus) 99,9
Productivity, m3 / h 30±10
Power no more, W 55
Rated voltage, V 220±22
Frequency, Hz 50±0,4
Noise level no more, dB 30
Lamp life, hrs 8000
Service life of the irradiator, years 5
Dimensions, mm 600×160×122
Weight, no more, kg 4
UV Air Recirculator Defender 2-15C closed type is designed to clean and disinfect air in the presence of people. It can work continuously throughout the day, preventing an increase in the level of microbial contamination of indoor air, regardless of the number of people in it and its category. Defender 2-15C is used for air purification both in hospitals and educational institutions, kindergartens, beauty parlors, and cultural institutions. Also, can be used at home.
The radiation source is a germicidal ultraviolet lamp that does not emit ozone and is safe for long-term use. The body of the irradiator is made of steel, coated with a special powder paint that is resistant to disinfectants.
Defender 1-15C is mounted either on the wall in a vertical position, or on a special stand (not included in the package, supplied separately).
Features of the closed-type germicidal recirculator Defender 1-15C can operate in the presence of people.
The radiation source is a low-pressure mercury discharge lamp, which gives short-wave UV radiation with a maximum of 253.7 nm, which has a bactericidal effect. To prevent the synthesis of ozone, the lamp bulb is made of special glass, which is impervious to wavelengths around 200 nm.
The service life of the UV lamp is at least 8000 hours.
Application
Long-term use in any premises in the presence of people or animals is possible.
General recommendations for using recirculators in closed rooms when working in the presence of people:
In the room, it is advisable to create an inflow of fresh air (from the street), for example, periodically ventilate.
It is not recommended to leave the recirculator turned on overnight, or sleep in a room with the recirculator turned on.
Depending on the volume and category of premises, the following processing time is recommended
Volume of premises, m3
Recommended processing time (not less, min.
Residential apartments, smoking rooms, public toilets and staircases of hospitals
Children's playrooms, school classes, orphanages, homes for the disabled, household premises of industrial and public buildings with a large crowd of people during a long stay
Chambers, offices and other premises of health care facilities (premises of the III category)
up to 60
60
90
120
from 60 to 120
120
180
240
Example: for effective treatment of a school class with an area of 35 m2 and a ceiling height of 3 m (room volume - 105 m3), at least 180 minutes of recirculator operation are required.
If you need to disinfect a large area, then pay attention to more powerful models of recirculators Defender 3-15C (with three lamps). For small spaces, there is a Defender 1-15C (with one lamp).
Number of germicidal lamps
2
Nominal lamp power, W
15
The performance of the irradiator with a bactericidal efficiency of % (for Staphylococcus aureus)
99,9
Productivity, m3 / h
30±10
Power no more, W
55
Rated voltage, V
220±22
Frequency, Hz
50±0,4
Noise level no more, dB
30
Lamp life, hrs
8000
Service life of the irradiator, years
5
Dimensions, mm
600×160×122
Weight, no more, kg
4